Original Article
Author Details :
Volume : 2, Issue : 2, Year : 2018
Article Page : 57-63
https://doi.org/10.18231/j.jco.2018.020
Abstract
Introduction: Study was carried out to compare the accuracy in producing digital formats of analog lateral cephalograms by taking a digital photograph and by scanning with a flatbed scanner.
Aim: To investigate whether taking a digital photograph of an analog lateral cephalometric radiograph is as accurate as using a flatbed scanner to scan the same radiograph for digitization.
Methods: Twenty lateral cephalograms were randomly selected from the records at a Dental College and Hospital in Belgaum. They were photographed with a digital camera and scanned with a flatbed scanner. Both images were then digitized with imaging software (Facad digital imaging program version 3.5). Set of predetermined measurements were transferred on all analog cephalograms. They were then measured on the imaging software. Student t test was used to test for statistically significant differences between the measurements. Statistical analysis used: Student paired t test.
Results: Angular measurements were deviating less from the original values after digitizing with both methods, but linear measurements were significantly changed.
Conclusion: It is acceptable to take photographs of analog cephalograms if only angular measurements are to be considered. However, these images cannot be accepted when considering linear measurements.
Keywords: Cephalograms, Comparison, Digital, Digitization.
How to cite : Khot O, Naik V, Shah S, Shetty K, Swamy K, Shenava S, Cephalometric Digitization: Converting Analog Cephalograms into Digital Format—A Comparative Study between Two Different Methods of Digitization. J Contemp Orthod 2018;2(2):57-63
This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International, which allows others to remix, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Received : 24/05/2018
Accepted : 19/06/2018
Viewed: 221
PDF Downloaded: 54