Journal of Contemporary Orthodontics

Official Publication of Indian Orthodontic Society



Evaluation of stress in bone by 9 different mini implants based on placement angle with relation to enmasse retraction force - An FEM study


Original Article

Author Details : Sai Teja Yenaganti*, Ankur Aggarwal, Vaibhav Misra, Prashant Sharma, Deepanshi Yadav, Devina Irengbam

Volume : 7, Issue : 4, Year : 2023

Article Page : 274-280

https://doi.org/10.18231/j.jco.2023.047



Suggest article by email

Abstract

Aim: The aim of this study was to evaluate the stress in bone at the mini implant site, placed at 5 different insertion angles with relation to en-mass retraction force using a Finite element analysis.
Objectives: Evaluation of stress in bone and their distribution pattern at the mini implants. Evaluation of stress distribution in surrounding cortical bone on application of retraction force at 5 different insertion angle.
Materials and Methods: Force applied was 200 grams on the model. The mini implants were modelled with varying diameters (1.3mm, 1.6mm, and 2.3mm) and varying lengths (7mm, 8mm, 10mm). The implant insertion angulations used were 30°, 45°, 60°, 90°, 120°.The pitch of the implant thread used was 0.5mm. This was fixed in all implant designs in this study. After the models were created, a process called meshing in which the models were divided individually into a finite number of elements,. The model was meshed with a tetrahedral configuration. The complete geometry has an assembly of discrete pieces called elements and is connected to gather at a finite number of points called nodes.
Results: In bone Von Mises stress was high in 1.3 × 8 mm implant at 60angulation and least was in 2.3 × 7 mm implant at 30angulation. In Implant of 1.3 × 10 mm in 90angulation showed high Von Mises stress and in Implant of 2.3 × 8 mm in 30angulation showed least Von Mises stress.
Conclusion: Mini implant which has got smaller diameter, long length and high inclination angle showed higher stresses when compared to other mini implants.


Keywords: Finite Element Method (FEM), Temporary Anchorage Devices (TADs), Skeletal


How to cite : Yenaganti S T, Aggarwal A, Misra V, Sharma P, Yadav D, Irengbam D, Evaluation of stress in bone by 9 different mini implants based on placement angle with relation to enmasse retraction force - An FEM study. J Contemp Orthod 2023;7(4):274-280


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International, which allows others to remix, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







Article History

Received : 16-06-2023

Accepted : 06-12-2023


View Article

PDF File   Full Text Article


Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.jco.2023.047


Article Metrics






Article Access statistics

Viewed: 515

PDF Downloaded: 158