Journal of Contemporary Orthodontics

Official Publication of Indian Orthodontic Society



Impact of recycling on efficiency and efficacy of copper nickel titanium wire and heat activated nickel titanium wire – An invitro study


Original Article

Author Details : Nibha Yadav, Piyush Bolya*, Vikas Goyal, Shuchi Singh, Neha Ajmera

Volume : 8, Issue : 3, Year : 2024

Article Page : 294-300

https://doi.org/10.18231/j.jco.2024.044



Suggest article by email

Abstract

Introduction: The aim of the study is to assess the feasibility of reusing copper nickel titanium wire and heat activated nickel titanium wires by evaluating the changes in efficiency and efficacy of wire after different sterilization techniques.
Materials and Methods: 120 total samples were taken. 60 samples of Damon copper nickel titanium (ORMCOTM) and 60 samples of heat activated nickel titanium wires (ORMCOTM). Damon CuNiTi and HANT were divided in 4 different sub groups of 15 samples each. 15 as received wires served as controlled group. The remaining wires were placed intraorally for a period of 4 weeks in patients undergoing orthodontic treatment. After 4 weeks, these wires were taken out. Remaining 45 wires were divided on the basis of sterilization method to be used. (autoclave, 70% isopropyl alcohol, 2% glutaraldehyde solution). Maximum load and tensile strength were tested using universal testing machine.
Results: No significant difference in mechanical properties of wires after various sterilization process (p value > 0.05). There no such difference in mechanical properties of controlled group wires and wires those are placed intraorally for 4 weeks.
Conclusion: Results suggested that there was no statistically significant difference in the Ultimate Tensile Strength and Maximum Load of Damon Copper Nickel-Titanium wire and Heat Activated Nickel Titanium wire following various sterilization procedures. These wires can be reused after sterilization.


Keywords: Ultimate tensile strength, Archwires, Heat activated nickel titanium wires, Sterilization, Copper-nickel-titanium


How to cite : Yadav N, Bolya P, Goyal V, Singh S, Ajmera N, Impact of recycling on efficiency and efficacy of copper nickel titanium wire and heat activated nickel titanium wire – An invitro study. J Contemp Orthod 2024;8(3):294-300


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International, which allows others to remix, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







Article History

Received : 09-03-2024

Accepted : 29-04-2024


View Article

PDF File   Full Text Article


Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.jco.2024.044


Article Metrics






Article Access statistics

Viewed: 383

PDF Downloaded: 145