Abstract

Background and Objectives: Lateral cephalogram plays a vital role in orthodontic diagnosis and treatment planning, from the advent of cephalometric radiography, whereas limited attention was given to posteroanterior cephalogram which evaluates skeletal discrepancies in transverse dimension. Thus, our study focuses on comparing the accuracy and reliability of fully automated AI driven software ‘WebCeph’, a semi-automated software ‘EasyCeph’ and manual tracing on posteroanterior cephalogram.
Materials and Methods: A sample of 30 pretreatment posteroanterior cephalometric radiographic digital images were collected and analyzed using manual tracing, WebCeph and EasyCeph with 20 landmarks (16 linear and 2 angular measurements). For manual tracing, hard copies of digital images were obtained, whereas for EasyCeph and WebCeph, direct digital images used for analysis. ANOVA Test was done to compare the measurements of each parameter among WebCeph, EasyCeph and manual tracing. Bonferroni post hoc test was performed for individual comparison among 3 groups. The intraoperator reliability were evaluated by correlation coefficient test after 1 month by retracing 5 randomly selected cephalograms.
Results: On comparing three methods, 6 out of 18 parameters showed statistically significant differences. On individual comparison, EasyCeph shows significant differences with its counterparts, whereas WebCeph and manual tracing values shows no statistically significant difference. The intraclass correlation coefficient shows strong correlation for manual tracing (0.84 to 0.95) and EasyCeph (0.78 to 0.89)
Conclusion: The automated cephalometric measurements from WebCeph are reasonably consistent, accurate and reliable when compared with Manual tracing and EasyCeph.


Keywords: Cephalometry, Computer assisted Diagnosis, Artificial intelligence, Digital radiography, Dental


How to cite : Natrajan K, Selvarajan K, Geevee A, Elango E, Sankar H, Krishnan P, Accuracy and reliability of webceph on posteroanterior cephalogram- A retrospective study. J Contemp Orthod 2024;8(4):491-495


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International, which allows others to remix, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







Article History

Received : 03-05-2024

Accepted : 02-11-2024


View Article

PDF File   Full Text Article


Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.jco.2024.074


Article Metrics






Article Access statistics

Viewed: 206

PDF Downloaded: 8