Journal of Contemporary Orthodontics

Official Publication of Indian Orthodontic Society


Kaurani, Daokar, Shehare, and Mantri: Clinical evaluation and assessment of the efficacy of platelet rich fibrin (PRF) on the stability of orthodontic implant


Introduction

Anchorage, defined as a resistance to unwanted tooth movement, is a prerequisite for the orthodontic treatment of dental and skeletal malocclusions.1 The growing demand for orthodontic treatment methods that require minimal compliance and provide maximal anchorage control, particularly for adults, has led to the expansion of implant technology in orthodontics.2

The basic requirement for the success of orthodontic mini-implants is sufficient primary stability. Primary stability basically comes from mechanical interlocking with the cortical bone when the mini-implant is placed. It is influenced by bone quality and quantity, surgical technique, and screw geometry.3

Even though mini-implants are being extensively used, a major drawback of Orthodontic mini-implants is their failure rate. The reported failure rate of mini-implants varies from 6.6 to 16.1%.4

Mini-implant placement generates stresses and strains along the length of the screw that damage the surrounding bone. Too much damage can lead to micromotion of the implant and early loss due to lack of stability.5

Research to improve the stability of mini-implants are on rise.

Platelet rich fibrin (PRF) is new generation platelet concentrate, a healing biomaterial, that has shown great potential for bone and soft tissue regeneration, without inflammatory reactions and may be used alone or in combination with bone grafts, promoting haemostasis, bone growth, and maturation. It consists of an autologous leukocyte-platelet-rich fibrin matrix6 composed of a tetra molecular structure, with cytokines, platelets, and stem cells within it,7, 8 which acts as a biodegradable scaffold that favours the development of micro-vascularization and is able to guide epithelial cell migration to its surface.7, 8, 9, 10

PRF may enhance the stability of mini-implants due to its healing property. Therefore, this study was undertaken to evaluate and assess the efficacy of PRF on the stability of orthodontic implant.

The present study investigated the effect of PRF on stability of mini-implants. A randomized clinical control trial was performed, with a focus on measuring the stability of mini-implant within the maxilla without loading following the extraction of first premolar teeth, to assess the effect of PRF on the miniimplant stability after 8 weeks using resonance frequency analysis, in comparison to that of the randomly allocated control group. The secondary outcomes expected was to evaluate the optimal loading time after the day of insertion of orthodontic micro-implants.

Materials and Methods

Trial design

The study was a single-centered, split-mouth randomized control trial to investigate the effectiveness of PRF on the stability of orthodontic mini-implant using resonance frequency analysis and secondary outcome.

Participants, eligibility criteria, and settings

The sample comprised patients who were undergoing comprehensive fixed orthodontic treatment with premolar extraction. Subjects who fulfilled the inclusion criteria (Table 1) were randomly allocated to 1 of the 2 groups. The lottery method of the simple random sampling technique was followed after informed consent was obtained from all the study subjects. On the one side was the test group (PRF group), and on the other side was the positive control (Non PRF) group. A total of 16 subjects were included in the study, and overall, 32 mini-implants were undertaken for assessment (16 mini-implants coated with PRF and 16 without PRF coating).

Sample size

A pilot study was done to determine the sample size of the 2 different groups of the study.11 The values obtained from each group were calculated and the effect size was obtained using G* power 3.1.9.2. Subsequently, we obtained a sample size of 13 per group. To avoid unexpected errors, outcomes and dropout, the size was rounded up to 16 per group. The samples were split into 2 groups in which interventions were carried out (Figure 1):

  1. Group 1: Among the patients in this group, the implants were coated with the PRF before insertion.

  2. Group 2: Among the patients in this group, were not coated with PRF before insertion.

The fresh PRF was made for each patient by following the given procedure:

Around 2 ml of whole venous blood was drawn from cubital vein after torniquet application in upper arm (Figure 1). A 5ml syringe with 26-gauge needle was used for blood extraction and blood was collected in each of the two sterile vacutainer tubes (test tube) of 5ml capacity without anticoagulant. Following blood collection, the vacutainer tubes were then placed in a centrifugal machine (Figure 2) at 3000 revolutions per minute (rpm) for 10 minutes. The resultant product (Figure 3) consisted of following layers:

  1. Top layer consists of straw-coloured cellular plasma.

  2. Middle layer consists of platelet rich fibrin.

  3. Bottom layer consists of R.B.C.

P.R.F and red corpuscle base was extracted using a sterile forceps from straw-coloured cellular plasma and then with help of a sterile scissor P.R.F. was cut-off from R.B.C and transferred onto a sterile dappen dish.16 implants were coated with PRF using zero size brush (Figure 4).

All the 18 titanium- Grade 5(Ti-6AI-4V) implants (1.5 x 6mm) were then inserted 8 mm from the alveolar crest between the upper first molar and premolar with a self-drilling method at 90º

The ISQ was measured using resonance frequency analyser at 6 different time intervals – at time of insertion(T0), 24 hours (T1), 2 weeks (T2), 4 weeks (T3), 6 weeks(T4) and 8 weeks(T5) after insertion in two directions i.e., mesiodistal direction (D1) and occlusogingival direction (D2). (Figure 4, Figure 5)

Result

Statistical analysis

The observations obtained in the study were subjected to statistical analysis, so as to get their interpretation. Data was coded, transferred and analysed on SPSS version 19. Mann Whitney test was used to compare the mean ISQ values measured in the two different directions and the ANOVA test was used for intragroup and intergroup comparison. Level of significance was set at p<0.05.

Figure 1

Blood withdrawal using 5ml syringe

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/72339f5a-b2d9-4164-bcfc-354984d17b6dimage1.png
Figure 2

Centrifugal machine

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/72339f5a-b2d9-4164-bcfc-354984d17b6dimage2.png
Figure 3

Micro implant coated with PRF

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/72339f5a-b2d9-4164-bcfc-354984d17b6dimage3.png
Figure 4

Reading inmesiodistal direction (D1).

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/72339f5a-b2d9-4164-bcfc-354984d17b6dimage4.png
Figure 5

Reading in occlusogingival direction (D2).

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/72339f5a-b2d9-4164-bcfc-354984d17b6dimage5.png
Graph 1

Comparison of Group A and Group B at different time interval

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/72339f5a-b2d9-4164-bcfc-354984d17b6dimage6.png

Table 1

Inclusion and exclusion criteria of the study

Inclusion criteria

Exclusion criteria

1. Subjects whose treatment plan will comprise of a micro-implant placement

1. Subjects having systemic disease affecting bone metabolism (Osteoporosis, Paget’s disease)/ wound healing (Diabetes)

2. Subjects with healthy periodontium

2. Subjects under any medications, steroids, bisphosphonates, calcium supplements

3. Subjects with good oral hygiene.

3. After insertion, data of subjects who missed examination appointments.

4. Age group above 18 years.

4. Subjects not willing to participate in the study.

Table 2

Comparison of the primary stability measured in the two directions for Group A bymann whitney U test.

Time interval

Mean Stability measured in direction 1

Mean stability measured in direction 2

p-value

Result

T0

62.94

62.81

0.727

Insignificant

T1

56.25

56.17

0.473

Insignificant

T2

46.54

47.15

0.76

Insignificant

T3

55.83

55.63

0.543

Insignificant

T4

59.23

59.29

0.703

Insignificant

T5

64.31

64

0.69

Insignificant

The mean ISQ between the direction D1 and D2 is statistically insignificant at any of the time periods for Group A.

Table 3

Comparison of the primary stability measured in the two directions for Group Bmann whitney U test.

Time interval

Mean Stability measured in direction A

Mean stability measured in direction B

p-value

Result

T0

39.98

38.40

0.06

Insignificant

T1

35.83

36.15

0.54

Insignificant

T2

30.75

30.67

0.73

Insignificant

T3

36.19

37.04

0.16

Insignificant

T4

38.54

38.81

0.60

Insignificant

T5

42.27

42.90

0.22

Insignificant

The mean ISQ between the direction D1 and D2 is statistically insignificant at any of the time periods for Group B.

Table 4

Intra group comparison of mean and standard deviation using in GroupA using ANOVA test

Group A

Mean

Std. Deviation

Std. Error

95% Confidence Interval for Mean

Min

Max

F`

Lower Bound

Upper Bound

Sig.

T0

61.55

3.772

.385

60.79

62.32

52

68

315.9

T1

56.21

3.172

.324

55.57

56.85

50

64

T2

46.84

4.578

.467

45.92

47.77

40

58

.00*

T3

55.26

2.796

.285

54.69

55.83

50

62

T4

59.26

2.485

.254

58.76

59.76

53

66

T5

64.16

2.773

.283

63.59

64.72

58

69

Table 5

Intra group comparison of mean and standard deviation using in Group B using ANOVA test

Group B

Mean

Std. Deviation

Std. Error

.95% Confidence Interval for Mean

Min

Max

F

Sig.

Lower Bound

Upper Bound

T0

39.19

3.522

.359

38.47

39.90

32

48

159.8

.00*

T1

35.99

2.553

.261

35.47

36.51

32

45

T2

30.71

4.292

.438

29.84

31.58

22

37

T3

36.61

2.569

.262

36.09

37.14

25

43

T4

38.68

2.763

.282

38.12

39.24

30

46

T5

42.58

2.315

.236

42.11

43.05

37

46

[i] *Statistically significant values between time intervals

Table 6

Comparison of mean and standard deviation of Group A and Group B at different time interval

Mean

Std. Deviation

Std. Error

95% Confidence Interval for Mean

Min

Max

Mean Difference

Lower Bound

Upper Bound

T0

Group A

61.55

3.772

.385

60.79

62.32

52

68

22.36

Group B

39.19

3.522

.359

38.47

39.90

32

48

T 1

Group A

56.21

3.172

.324

55.57

56.85

50

64

20.22

Group B

35.99

2.553

.261

35.47

36.51

32

45

T2

Group A

46.84

4.578

.467

45.92

47.77

40

58

16.14

Group B

30.71

4.292

.438

29.84

31.58

22

37

T3

Group A

55.26

2.796

.285

54.69

55.83

50

62

18.65

Group B

36.61

2.569

.262

36.09

37.14

25

43

T4

Group A

59.26

2.485

.254

58.76

59.76

53

66

20.58

Group B

38.68

2.763

.282

38.12

39.24

30

46

T5

Group A

64.16

2.773

.283

63.59

64.72

58

69

21.57

Group B

42.58

2.315

.236

42.11

43.05

37

46

Statistically insignificant findings were observed when direction D1 i.e., Mesio-distal direction when compared to direction D2 i.e., Occluso-gingival direction using Mann Whitney test at T0, T1, T2, T3, T4 and T5 in both the groups. (Table 2, Table 3)

Statistically significant findings were found when group A (experimental group) was compared to group B (control group) using ANOVA test (p<0.05). The stability of implant of group A at each time interval was greater than group B. (Table 4, Table 5) (Figure 6)

The difference in mean ISQ for the intragroup comparison by using ANOVA test was also found statistically significant. The implant stability was found to be high at T0 and reduces till T2 and then increases through T3 to T5 in both the groups. The stability was highest at T5. (Table 6, Table 5)

Discussion

In this study, statistically significant findings were found when group A (Experimental group) was compared to group B (Control group) using ANOVA test (p<0.05).

The stability of implant of group A at each time interval was greater than group B. This shows that implants coated with PRF have increased its stability suggesting PRF can significantly enhance the implant stability. This may be because it consists of an autologous leukocyte-platelet-rich fibrin matrix6 composed of a tetra molecular structure, with cytokines, platelets, and stem cells within it,7, 8 which acts as a biodegradable scaffold9 that favours the angiogenesis and is able to guide epithelial cell migration to its surface.7, 10 The mechanism which was followed here was that, fibrinogen which was initially concentrated in the high part of the tube, combined with the circulating thrombin due to centrifugation, to form fibrin. A fibrin clot was then obtained in the middle of the tube, just between the red corpuscles at the bottom and acellular plasma at top. Platelets were trapped massively in the fibrin meshes.5

In intragroup comparison of ISQ values at different time intervals were analyzed using ANOVA Test it was observed that the implant stability was higher at T0 and reduces till T2 and increasing through T3 to T5. The stability was lowest at T2 and highest at T5.

This shows that the primary stability of implant is best at the time of insertion, however the stability gradually declines from 24 hours till 2nd week after implant insertion which may be due to inflammatory response of the adjacent tissues to the trauma caused at the time of implant placement. The stability then starts increasing after 2nd week of implant stability shows that healing sets in after the initial inflammatory response and improves the stability. The highest ISQ value was shown at 8 weeks of duration. Suggesting that the best time to load the implants will be immediately after the placement of the implant or after 8th week of insertion of implant.

With above findings we can also conclude that the best time of loading the implant is at the time of insertion i.e., immediate loading is recommended.

The result of this study could not be compared with any other studies as there were no studies found regarding use of PRF with mini-implants in the literature.

Conclusion

In this study, PRF coating has shown a promising result in terms of increase in stability of implants. So, with the use of PRF, the stability of mini-implants can be increased by chairside with minimally invasive procedure. There is a scope to evaluate the effect of PRF of micro-implants on primary stability with loading the mini-implants with an increased sample size for long period of time.

The limitation of this study is that it includes the limited sample size and the primary stability was measured without loading the micro-implants which would also affect the primary stability. Another drawback is that only a single type of micro-implants from a same company was used. Further investigations using different types of mini-implants at different positions is recommended.

Source of Funding

None.

Conflict of Interest

None.

References

1 

MA Papadopoulos F Tarawneh The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review.Oral Surg Oral Med Oral Pathol Oral Radiol Endodontol20071035615

2 

KK Garg M Gupta Assessment of stability of orthodontic mini-implants under orthodontic loading: A computed tomography studyIndian J Dent Res201526323743

3 

A Singh S Kannan N Arora Y Bajaj A Revankar Measurement of mini-implant stability using resonance frequency analysisAngle Orthod20188322308

4 

M Schätzle R Männchen M Zwahlen N P Lang Survival and failure rates of orthodontic temporary anchorage devices: a systematic reviewClin oral Implants Res20092012135160

5 

CY Pan ST Chou YC Tseng YH Yang CY Wu TH Lan Influence of different implant materials on the primary stability of orthodontic mini-implantsKaohsiung J Med Sci2012281267381

6 

V Gupta VK Bains GP Singh A Mathur R Bains Regenerative potential of platelet rich fibrin in dentistry: Literature review. Asian J Oral Health Allied Sci2011112331

7 

DM Dohan J Choukroun A Diss SL Dohan AJ Dohan J Mouhyi Platelet-rich fibrin (PRF): a second-generation platelet concentrate. Part II: platelet-related biologic featuresOral Surg Oral Med Oral Pathol Oral Radiol Endod200610134550

8 

J Choukroun A Diss A Simonpieri MO Girard C Schoeffler SL Dohan Platelet-rich fibrin (PRF): a second-generation platelet concentrate. Part IV: clinical effects on tissue healingOral Surg Oral Med Oral Pathol Oral Radiol Endod200610135660

9 

Q Li S Pan SJ Dangaria G Gopinathan A Kolokythas S Chu Platelet-rich fibrin promotes periodontal regeneration and enhances alveolar bone augmentationBiomed Res Int201363804310.1155/2013/638043

10 

DM Dohan J Choukroun A Diss SL Dohan AJ Dohan J Mouhyi Platelet-rich fibrin (PRF): a second-generation platelet concentrate. Part III: leucocyte activation: a new feature for platelet concentrates?Oral Surg Oral Med Oral Pathol Oral Radiol Endod20061013515

11 

HJ Kaurani ST Daokar SN Vilas SK Deepakrao TP Jaywant Innovative Method to Increase the Stability of Mini-ImplantJ Res Adv Dent202213110711



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International, which allows others to remix, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

  • Article highlights
  • Article tables
  • Article images

Article History

Received : 23-11-2022

Accepted : 15-12-2022


View Article

PDF File   Full Text Article


Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.jco.2023.003


Article Metrics






Article Access statistics

Viewed: 620

PDF Downloaded: 146