Agrawal and Shashikala Kumari V.: Evaluation of skeletal changes in glenoid fossa, condylar head and articular space following fixed functional appliance therapy using cone beam computed tomography – A clinical prospective study


Introduction

In clinical setting, skeletal Class II malocclusion may manifest either by prognathic maxilla and orthognathic mandible, or orthognathic maxilla and retrognathic mandible, or a combination of the two.1, 2

One of the recommended therapeutic approaches to Class II malocclusion in growing patients, who are around circumpubertal growth period, is functional jaw orthopedics through the primary mechanism of mandibular advancement. This forms the basis of growth modulation therapy.

Contrary to removable functional appliances, fixed functional devices do not require patient’s collaboration and can be worn full time in association with multibracket therapy, so that skeletal and dental discrepancies can be corrected in a single phase treatment. This modality significantly reduces treatment duration and cost factor.3

Shortcomings of 2D diagnostic imaging techniques paved way to 3D imaging techniques, which have provided a new possibility for orthodontic diagnosis and treatment evaluation. The application of recently introduced cone beam computed tomography (CBCT) to craniofacial region provides an alternative to traditional computed tomography (CT) systems with advantages of reduced radiation and lower expenditure. 3D superimposition protocol uses a ridged voxel-based registration technique that eliminates examiner bias in the registration process.4

Since Powerscope has been recently introduced to the orthodontic fraternity, very limited studies have been published regarding this appliance till date. So the aim of this study was to evaluate skeletal changes produced in the condyle, glenoid fossa and articular space following Powerscope appliance, in collaboration with multibracket fixed appliance treatment, using cone beam computed tomography.

Objectives of the study were to measure position, length and height of condyle, glenoid fossa angle and articular space at anterior, middle and posterior regions using CBCT scans following Powerscope appliance treatment.

Materials and Methods

Twenty patients with mandibular retrognathia visiting the institute’s Department of Orthodontics were included in this study.

All subjects and their parents were informed about the procedures to be performed and signed informed consent was obtained from the parent/guardian, as all patients were minor.

The study was approved by Institutional Ethics Committee and review board, Government Dental College and Research Institute, Bangalore, vide letter no. GDCRI/ACM(2)/3562/2015-16.

Young growing patients presenting with Class II Division 1 skeletal and dental malocclusion with mandibular retrognathia and within Cervical Vertebral Maturity Indicator Stage 4 and 5 5 were included in the study.

Subjects with CVMI stage < 3 and > 5, subjects having any periodontal disease(s), subjects having undergone any previous orthodontic treatment(s), subjects with any history or symptoms of temporomandibular joint disease(s) or any systemic disease(s) affecting bone metabolism were excluded from the study.

Eleven growing patients, who fulfilled the selection criteria, were chosen. Following their preliminary extraoral and intraoral examination, diagnostic records were made (Figure 1, Figure 2), which confirmed orthognathic maxilla, retrognathic mandible and horizontal to average growth pattern. A CBCT scan was obtained of both temporomandibular joints before commencement of treatment (T1) to check for the position of condyle, condylar length, condylar height, glenoid fossa and articular space using KODAK 9000 3D Extraoral Imaging System (Carestream Health, Rochester, New York, USA) and data were exported as DICOM images to CS 3D Imaging Software (Carestream Health, Rochester, New York, USA).

Figure 1

Extraoral pre-treatment photographs and powerscope appliance

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage1.png
Figure 2

Intraoralpre-treatment photographs

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage2.png

After CBCT scans were analyzed, the above mentioned variables were assessed on DICOM images using the same software. The field of view was confined to both TMJs so that condylar head, glenoid fossa and external auditory meatus were visualized. To carry out the measurements on CBCT scan, conventional sagittal slicing was used. A horizontal line was constructed passing through the tangent of external acoustic meatus, which was parallel to the true horizontal.6 The section of the CBCT was then aligned such that maximum length and width of the external auditory meatus was obtained. After locating the midpoint of external auditory meatus, a line, perpendicular to the tangent and passing through the midpoint, was drawn. Linear measurement was obtained by drawing a line from the center of the condylar head to the midpoint of external auditory meatus parallel to the tangent6 (Figure 3 a-c).

Figure 3

a-c :   a1 – Pre-Treatment (T1) Condylar Position, a2 – Post-Treatment (T2) Condylar Position, b1 – Pre-Treatment (T1) Anterior and Posterior Articular Spaces, b2 – Post-Treatment (T2) Anterior and Posterior Articular Spaces, c1 – Pre-Treatment (T1) Middle Articular Space, c2 – Post-Treatment (T2) Middle Articular Space

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage3.png

Glenoid fossa angle was measured by drawing a tangent to anterior and posterior slopes of glenoid fossa6 (Figure 4, a-c). Linear measurements between anterior and posterior slopes of glenoid fossa and condylar head at three different locations i.e., anterior,7 middle8 and posterior,7 were taken for articular space (Figure 3, a-c). Linear measurement was carried out to get the size of condylar head between points on anterior and posterior curvature of condylar head.9 Condylar height was obtained by drawing a perpendicular from the highest point on the condylar head to a tangent to the deepest point on sigmoid notch9 (Figure 4, a-c).

Figure 4

a-c:   a1 – Pre-Treatment (T1) Glenoid Fossa Angle, a2 – Post-Treatment (T2) Glenoid Fossa Angle, b1 – Pre-Treatment (T1) Condylar Length, b2 – Post-Treatment (T2) Condylar Length, c1 – Pre-Treatment (T1) Condylar Height, c2 – Post-Treatment (T2) Condylar Height

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage4.png

Firstly, 0.022x0.028” preadjusted edgewise MBT brackets (American Orthodontics, Sheboygan, WI, USA) were bonded to the patients’ dentition. Upper and lower second molars were also banded/bonded in order to minimize intrusive forces on the molars. A transpalatal arch was placed to maintain transverse dimension of the maxillary arch. After initial leveling and aligning, 0.019x0.025” U/L rectangular stainless steel archwires were placed for 1 month. Labial root torque was provided in the lower archwire in mandibular anterior region and archwires were cinched back in order to prevent dumping of mandibular anteriors. Entire maxillary and mandibular arches were consolidated using 0.009” stainless steel ligature. Later, Powerscope Appliance (American Orthodontics, Sheboygan, WI, USA) (Figure 1) was placed. Intraoral photographs (Figure 2) were taken. Patients were called after 10 days for an initial check-up, then once every 4 weeks for regular check-up for a period of 6-8 months. Monthly appointments included assessment of attainment of pterygoid reflex, any breakages of the fixed appliance, and checkup for any discomfort and regular motivation. Appliance was sequentially activated by using crimpable shims (available in 2 mm and 3 mm sizes) depending on the amount of skeletal discrepancy in each patient’s mouth, until edge-to-edge bite was obtained. After completion of 6-8 months of treatment with Powerscope appliance, CBCT of both temporomandibular joints were repeated (T2) to quantify skeletal changes produced in glenoid fossa, condylar head and articular space and to compare with linear and angular measurements from pre-treatment scans (T1). Following complete treatment duration of approximately 24 months, post-treatment extraoral and intraoral records were taken (Figure 5, Figure 6, Figure 7). Removable retention appliance with inclined plane for maxillary dentition and fixed lingual retainer for mandibular dentition was placed. Out of 11 patients, 3 did not report for further treatment so total 8 patients completed the Powerscope appliance therapy successfully.

Figure 5

Intraoral photographs withpowerscope appliance

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage5.png
Figure 6

Extraoral post-treatment photographs

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage6.png
Figure 7

Intraoralpost-treatment photographs

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage7.png

All measurements were carried out by two operators, to avoid intra- and inter-observer errors. Double assessment of each parameter was done at least 1 week apart to check for intra- & inter-examiner reliability which was excellent as coefficient of correlation was above 0.96 for all CBCT measurements.

The data obtained were subjected to statistical analysis. Means, standard errors, and standard deviations were tabulated, which were calculated using SPSS (Statistical Package for Social Sciences Software, SPSS Inc., Chicago, Ill, USA).

Results

Sample size included 5 females (45.45%) and 6 males (54.54%), with a mean age of 12.50 years for female patients and 13.66 years for male patients.

The statistical test used in this study was paired t-test. The level of significance (α) was set at 0.05.

Statistically significant forward positioning of the mandibular condyle and increase in condylar length, condylar height, middle & posterior articular space was seen on both sides. Statistically significant decrease in anterior articular space and glenoid fossa angle was seen (Figure 8, Figure 9, Figure 10). The mean difference between T1 & T2 on both sides of above variables is shown in Table 1, Table 2. In all of the variables studied, statistically significant difference was not seen between either side, so mean of both sides is taken (Table 2).

Figure 8

Comparison of different variables between pre-treatment & post-treatment on CBCT scans

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage8.png
Figure 9

Comparison ofglenoid fossa angle on right & left sides and mean value between pre treatment and post-treatment on CBCT scans

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage9.png
Figure 10

Comparison of mean changes in variables betweenpre-treatment and post-treatment on CBCT scans

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/4c50adbf-4ea6-46d6-8101-2b941253637aimage10.png
Table 1

Comparison of different variables between pre-treatment & post-treatment on CBCT scans

S. No.

Parameter (in mm)

Pre-Treatment (T1)

Post-Treatment (T2)

Mean Difference

P Value

Mean

SD

Mean

SD

1.

Left Condylar Position

11.48

± 0.49

12.72

± 0.57

1.24

0.000

2.

Right Condylar Position

11.42

± 1.38

12.35

± 1.36

0.93

0.001

3.

Left Anterior Articular Space

1.49

± 0.27

1.30

± 0.22

0.19

0.004

4.

Right Anterior Articular Space

1.41

± 0.29

1.14

± 0.13

0.27

0.028

5.

Left Middle Articular Space

2.86

± 0.58

5.30

± 0.56

2.44

0.000

6.

Right Middle Articular Space

2.51

± 0.43

5.18

± 0.57

2.67

0.000

7.

Left Posterior Articular Space

3.09

± 0.40

4.79

± 0.61

1.70

0.000

8.

Right Posterior Articular Space

3.00

± 0.53

5.00

± 0.96

2.00

0.000

9.

Left Glenoid Fossa Angle*

81.63

± 3.58

79.88

± 3.36

1.75

0.001

10.

Right Glenoid Fossa Angle*

80.75

± 4.74

79.50

± 3.93

1.25

0.006

11.

Left Condylar Length

9.69

± 0.54

10.00

± 0.76

0.31

0.012

12.

Right Condylar Length

9.85

± 0.52

10.06

± 0.66

0.21

0.042

13.

Left Condylar Height

15.29

± 1.93

15.99

± 2.10

0.70

0.003

14.

Right Condylar Height

15.04

± 1.90

15.76

± 1.99

0.72

0.005

[i] * Indicates values in Degrees

Table 2

Comparison of different variables on right and left sides between pre-treatment & post-treatment on CBCT scans

S.No.

Parameter (in mm)

Left

Right

Mean Difference

P Value

Average Change

Mean

SD

Mean

SD

1.

Condylar Position

1.24

± 0.50

0.93

± 0.46

0.31

0.557

1.08

2.

Anterior Articular Space

0.19

± 0.12

0.27

± 0.28

0.08

0.820

0.23

3.

Middle Articular Space

2.44

± 0.86

2.67

± 0.44

0.23

0.449

2.55

4.

Posterior Articular Space

1.70

± 0.35

2.00

± 0.55

0.30

0.498

1.85

5.

Glenoid Fossa Angle*

1.75

± 0.89

1.25

± 1.58

0.50

0.700

1.50

6.

Condylar Length

0.31

± 0.26

0.21

± 0.24

0.10

0.385

0.26

7.

Condylar Height

0.70

± 0.43

0.72

± 0.41

0.02

0.556

0.71

[i] * Indicates values in Degrees

Discussion

The treatment of Class II malocclusion has always presented with a challenge to the orthodontists.

Over time, although various fixed functional jaw orthopaedic appliances were developed for correction of Class II malocclusion with mandibular retrusion, Powerscope appliance was used in this study owing to its certain advantages. The problem of fatigue failure is addressed by its telescopic spring architecture, which is usually the case with rigid fixed functional appliances, and hence, greatly reduces the number of patient’s emergency visits to the orthodontist.10 This appliance is factory manufactured and doesn’t require any chairside assembly. Appliance placement is not cumbersome, since it can be directly attached to the archwire. Activation is done by adding crimpable shims of predefined dimensions for stepwise advancement of mandible and this greatly reduces the orthodontist’s chairside time during follow-up activation appointments.

According to Baccetti et al,11 when twin block appliance is used, best results of orthopedic correction are obtained when patients are treated during or slightly after the onset of pubertal peak.

There are instances when patients report to the orthodontist seeking treatment when he/she has reached past the age of pubertal growth spurt. By then, maximum percentage of growth has already been completed, with only residual condylar growth to be completed. But according to Aras,7 Konik,12 and Ruf and Pancherz,13 mandibular growth can extend beyond puberty, and minimal residual growth can only be stimulated with fixed functional appliances. According to Ruf and Pancherz,13, 14 Herbst appliance is most successful in treatment of Class II patients who are at the end of growth period. According to Pancherz’s viewpoint,5 orthopedic growth adaptation with the use of Herbst appliance is a useful alternative to orthognathic surgery in borderline adult skeletal Class II cases and that owing to remodeling capacity of TMJ in adult patients, it can be used for growth modulation in young adults for bringing about skeletal changes in the TMJ. The phenomenon of ‘Cephalocaudal Gradient of Growth’ also applies in the craniofacial region, as elsewhere in the body, wherein mandible, being distal to the cranium, continues its sagittal growth until late adolescence whereas maxilla, being in proximity to the cranium, completes its growth before the mandible.15

Thus, in this study, case selection was done keeping above factors in mind.

As stated earlier, owing to its high degree of accuracy and reliability9, 16, 17, 18 in maxillofacial imaging, CBCT of TMJ was preferred for measuring the said parameters.

Treatment effect on condyles

A forward shift in condylar position obtained in this study (Table 1, Table 2) is in agreement with Wadhawan et al.6 where an MRI study concluded that forward condylar shift of 1.20 mm was seen following functional appliance treatment.

An increase in the condylar length and height (Table 1, Table 2) contributed to overall increase in mandibular length. In previous studies, a similar change in condylar dimensions after Herbst appliance therapy was reported by LeCornu et al.,4 Ruf and Pancherz.19

Treatment effect on glenoid fossa

In this study, bone remodeling in the glenoid fossa can be explained by a decrease in glenoid fossa angle (Table 1, Table 2) which indicates bone deposition on the posterior slope and bone resorption along the anterior slope of glenoid fossa. Similar changes were noticed by LeCornu et al.4 and Ruf and Pancherz19 while using Herbst appliance. LeCornu et al.4 reported bone resorption along the anterior wall (right, 1.69 mm; left, 1.43 mm) with deposition along the posterior wall of glenoid fossa (right, 0.59 mm; left, 0.79 mm).

Ruf and Pancherz19 reported that remodeling of the glenoid fossa occurred at inferior part of anterior surface of post-glenoid spine and decreased progressively towards the superior part of the fossa. Findings in the glenoid fossa in our study are in agreement with findings of the study mentioned above.

Rabie et al.20 and Jung21 have associated the changes in the glenoid fossa to changes occurring at the cellular level. They found that mandibular protrusion resulted in osteoprogenitor cells being oriented in the direction of pull of posterior fibers of articular disc and also resulted in a considerable increase in bone formation in the glenoid fossa. Changes in the glenoid fossa observed in this study could be probably due to similar cellular responses.

It has been reported that new bone formation seems to be induced by tensile forces of posterior fibrous tissues of articular disc transmitted to the periosteum of the glenoid fossa. This indicated that at least two etiological factors might be responsible for growth modification mechanism: force of viscoelastic tissues and force transduction. The viscoelastic properties are associated with the stretched retrodiscal tissues, fibrous capsule, and sticky, hydrophilic synovial fluids communicating with the condyle and the glenoid fossa, described in the growth relativity hypothesis.22 Also, according to Voudouris,23 bone formation found in experimental animals up to the articular eminence, where there is no retrodiscal attachment, has also been linked to force transduction, which appears to be produced from the attachment of the retrodiscal tissues at the anterior aspect of the fossa. Hence, changes in the glenoid fossa could be due to new bone formation as explained by above studies.

Treatment effect on articular space

In this study, anterior articular space was found to be reduced whereas middle and posterior articular spaces increased (Table 1, Table 2).

From above results, it is clear that skeletal changes were seen in both sagittal and vertical planes with respect to condyle and in sagittal plane with respect to glenoid fossa which contributed to statistically significant overall increase in mandibular length. Studies conducted by Wadhawan6 and Baysal24 on effects of twin block concluded that treatment effects were mainly due to mandibular skeletal changes by anterior relocation of Condyle-Glenoid Fossa (C-GF) complex. As mentioned in previous studies conducted on appliances like Herbst, Eureka spring, Jasper Jumper, Forsus nitinol flat-spring and Forsus Fatigue Resistant Device by Cacciatore,3 Aras,7 Karacaya,25 Servello,26 Perinetti,27 Franchi,28 Aslan29 Zymperdikas,30 and Celikoglu31 respectively, as well as studies on Powerscope appliance particularly conducted by Agarwal,32 Antony,33 Ansari,34 Singaraju,35 Varghese,36 and Kaur,37 the overall correction of Class II malocclusion by fixed functional appliances is mainly dentoalveolar in nature. But in this study, only skeletal changes in condyle-glenoid fossa region were evaluated, whereas changes in dentoalveolar structures before and after Powerscope appliance treatment were not taken into account.

Besides skeletal changes induced by Powerscope appliance in the C-GF region, other factors such as relief of dental intercuspation due to the appliance and intrinsic genetic potential of the patient favoring residual sagittal mandibular growth, ought to be taken into consideration. However, there is a complex interplay of above mentioned factors which govern the growth modulation therapy using functional appliances which might have played a role in sagittal correction of the mandible.

More evidence is required in order to substantiate long term skeletal and dentoalveolar effects caused by Powerscope appliance.

Conclusion

When powerscope appliance was incorporated for the correction of skeletal Class II malocclusion, it can be concluded that:

  1. An average forward shift of mandibular condyle by 1.08 mm was seen after 6-8 months of treatment.

  2. An increase in condylar length (0.26 mm) and height (0.71 mm) was seen, which may have contributed to increase in mandibular length.

  3. Changes in anterior and posterior slopes of the glenoid fossa may have led to decrease in glenoid fossa angle (1.50o).

  4. An average decrease in anterior articular space by 0.23 mm and increase in middle and posterior articular space by 2.55 mm and 1.85 mm respectively, was seen which could be due to forward shift of the condyle and changes in the glenoid fossa.

Acknowledgement

We would like to extend our acknowledgement to Dr. Alok Chaurasia, MD, who helped us with the statistical analysis of this study, and Dr. Vinod Kumar, MDS, who helped us in interpreting and analyzing the CBCT results.

Source of Funding

None.

Conflict of Interest

None.

References

1 

D Venes Taber's Cyclopedic Medical Dictionary20th 20051298

2 

J Daskalogiannakis Glossary of Orthodontic TermsQuintessence Publishing Co, Inc. BerlinGermany2000284

3 

G Cacciatore L Tomas HG Alvetroc L Giuntini V Franchi Treatment and post-treatment effects induced by the Forsus appliance - A controlled clinical studyAngle Orthod2014846101027

4 

M Lecornu HS Lucia Cevidanes H Zhu C Da Wu B Larson Three-dimensional treatment outcomes in Class II patients treated with the Herbst appliance: A pilot studyAm J Orthod Dentofac Orthop2013144681848

5 

H Pancherz Dentofacial orthopedics or Orthognathic surgery: Is it a matter of age?Am J Orthod Dentofac Orthop2000117557174

6 

N Wadhawan S Kumar OP Kharbanda R Duggal R Sharma Temporomandibular joint adaptations following two-phase therapy: an MRI studyOrthod Craniofac Res200811423550

7 

A Aras AE Saracoglu H Gezer NS Aras Comparison of treatments with the Forsus fatigue resistant device in relation to skeletal maturity: A cephalometric and magnetic resonance imaging studyAm J Orthod Dentofac Orthop201114061641

8 

K Ikeda A Kawamura Assessment of optimal condylar position with limited cone-beam computed tomographyAm J Orthod Dentofac Orthop2009135495501

9 

ML Hilgers WC Scarfe JP Scheetz AG Farman Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiographyAm J Orthod Dentofac Orthop2005128680314

10 

MA Papadopoulos Orthodontic Treatment of Class II Malocclusion in Non-compliant PatientElsevier PublishingChina2006102

11 

T Baccetti L Franchi LR Toth JA Mcnamara Treatment timing for Twin-block therapyAm J Orthod Dentofac Orthop2000118215970

12 

M Konik H Pancherz K Hansen The mechanism of Class II correction in late Herbst treatmentAm J Orthod Dentofac Orthop19971128791

13 

S Ruf H Pancherz Dentoskeletal effects and facial profile changes in young adults treated with the Herbst applianceAngle Orthod199969323985

14 

S Ruf H Pancherz Temporomandibular joint remodeling in adolescents and young adults during Herbst treatment: A prospective longitudinal magnetic resonance imaging and cephalometric radiographic investigationAm J Orthod Dentofac Orthop1999115660725

15 

WR Proffit HW Fields DM Sarver Contemporary Orthodontics4thMosby ElsevierSt. Louis, Missouri, USA 20072830

16 

N Ye Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomographyAm J Orthod Dentofac Orthop2012142687987

17 

OB Honey WC Scarfe MJ Hilgers K Klueber AM Silveira BS Haskell Accuracy of cone-beam computed tomography imaging of the temporomandibular joint: Comparisons with panoramic radiology and linear tomographyAm J Orthod Dentofac Orthop2007132442967

18 

M Berco JR Rigali PH Miner RM Deluca S Anderson NK Will Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skullAm J Orthod Dentofac Orthop20091324178

19 

S Ruf H Pancherz Temporomandibular joint growth adaptation in Herbst treatment: a prospective magnetic resonance imaging and cephalometric roentgenographic studyEur J Orthod199820437586

20 

AB Rabie Z Zhao G Shen EU Hägg W Robinson Osteogenesis in the glenoid fossa in response to mandibular advancementAm J Orthod Dentofacial Orthop20011194390400

21 

M Jung Fixed-functional appliance treatment combined with growth hormone therapyAm J Orthod Dentofacial Orthop2017152402414

22 

JC Voudouris MM Kuftinec Improved clinical use of Twin-block and Herbst as a result of radiating viscoelastic tissue forces on the condyle and fossa in treatment and long-term retention: Growth relativityAm J Orthod Dentofac Orthop2000117324766

23 

J Voudouris DG Woodside G Altuna MM Kuftinec G Angelopoulos PJ Bourque Condyle-fossa modifications and muscle interactions during Herbst treatment, Part 2. Results and conclusionsAm J Orthod Dentofac Orthop200312411329

24 

A Baysal T Uysal Dentoskeletal effects of Twin Block and Herbst appliances in patients with Class II division 1 mandibular retrognathyEur J Orthod201436236164

25 

S Karacaya E Akina H Olmezb AU Gurtonb D Sagdi Forsus Nitinol Flat Spring and Jasper Jumper Corrections of Class II division 1 MalocclusionsAngle Orthod200676466672

26 

DF Servello DW Fallis L Alvetro Analysis of Class II patients, successfully treated with the straight-wire and Forsus appliances, based on cervical vertebral maturation statusAngle Orthod2015851806

27 

G Perinetti J Primozic G Furlani L Franchi L Contardo Treatment effects of fixed functional appliances alone or in combination with multibracket appliances: A systematic review and meta-analysisAngle Orthod201585348092

28 

L Franchi L Alvetro V Giuntini C Masucci E Defraia T Baccetti Effectiveness of comprehensive fixed appliance treatment used with the Forsus Fatigue Resistant Device in Class II patientsAngle Orthod201181467883

29 

BI Aslan E Kucukkaraca C Turkoz M Dincer Treatment effects of the Forsus Fatigue Resistant Device used with miniscrew anchorageAngle Orthod20148417687

30 

VF Zymperdikas V Koretsi SN Papageorgiou MA Papadopoulos Treatment effects of fixed functional appliances in patients with Class II malocclusion: a systematic review and meta-analysisEur J Orthod201538211339

31 

M Celikoglu T Unal M1 Bayram C Candirli Treatment of a skeletal Class II malocclusion using fixed functional appliance with miniplate anchorageEur J Dent2014827680

32 

L Agarwal K Singh R Tandon Treatment of Class II Division 2 malocclusion using Powerscope: A case reportOrthod J Nep201881637

33 

T Antony V Amin S Hegde S Hegde D Shetty BM Khan The evaluation and clinical efficiency of Powerscope: Original researchJ Int Soc Prev Commun Dent20188326470

34 

A Ansari AK Jain A Singh P Sharma M Adil Management of skeletal Class II malocclusion in non-compliant patient using Powerscope: A case reportOrthod J Nepal2019927781

35 

GS Singaraju V Vannala SA Ankisetti P Mandava VR Ganugapanta D Unnam Evaluation of sagittal changes in Class II Division 2 patients with decelerating phase of growth by Powerscope appliance: A retrospective cephalometric investigationJ Pharm Bioallied Sci201911220815

36 

RM Varghese AK Subramanian S Sreenivasagan Comparison of dentoskeletal changes in skeletal Class II cases using two different fixed functional appliances: Forsus Fatigue Resistant Device and Powerscope Class II Corrector: A clinical studyJ Int Oral Health202113323478

37 

GJ Kaur G Gandhi M Khanna A Loomba A Sharma A cephalometric evaluation and comparison of skeletal, dentoalveolar, and soft tissue changes brought about by Forsus Fatigue Resistant Device and Powerscope Fixed Functional ApplianceJ Indian Orthod Soc202256322736



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International, which allows others to remix, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

  • Article highlights
  • Article tables
  • Article images