Kalia, Attri, Misra, Joshi, Yadav, and Kalia: Accuracy of lab scanners in establishing dental measurements: In-vitro study


Introduction

The use of study models in orthodontics has been acknowledged as an essential and important component of the specialty. Traditionally, plaster orthodontic models, direct measurements, 2D images, and radiographs 1 have been employed for obtaining information.

Digital images and 3D models are increasingly used as orthodontic record in numerous practices throughout the world in order to enhance the efficacy and accuracy of the record- taking. The orthodontist can do standard measurements and acquire various analyses from the digitalized models.2

The published material contains inconsistent information about the precision of dental dimensions obtained from digital models generated via scanning plaster models and provides scant information about digital models created by scanning impressions. Additionally, there are no studies that evaluate the dependability and correctness of model analysis performed on 3D models created from dental impressions made using rubber base impression material.

Determining the accuracy of the measurements taken by the lab scanner on rubber-based impressions, the scanned stone cast, and the traditional stone cast by digital vernier calliper was the intent of this study.

The goals of this research were to compare accuracy between measurements made

  1. On a stone cast manually by a digital vernier calliper.

  2. On the same stone cast by a lab scanner.

  3. On the impression by a lab scanner.

Materials and Methods

  1. Source of Data: This study was carried out on patients in the Department of Orthodontics and Dentofacial Orthopaedics at Divya Jyoti (D.J) College of Dental Science and Research, Modinagar. U.P.

  2. Sample design: In-vitro study

  3. Study period: 1 year

  4. Sample size: 20

Inclusion criteria

  1. No prior orthodontic treatment history.

  2. No missing tooth anterior to first molars.

  3. Absence of supernumerary tooth.

  4. Patients with all permanent teeth.

Exclusion criteria

  1. Congenital anomalies

  2. Grossly decayed teeth

  3. Congenitally missing teeth

  4. Fractured teeth

  5. Caries involving proximal surfaces

  6. Presence of retained deciduous teeth

Materials and Methods

  1. Maxillary perforated impression trays (Figure 1)

  2. Rubber base impression material (Condensation C silicone elastomeric impression material (Figure 2)

  3. Type III Dental stone (Figure 3)

  4. Digital calliper (DIGE 150-3V Battery (Figure 4)

  5. Lab scanner (3 shapes series E3 1tb1920033b (Figure 5)

  6. Software for 3 D Analysis (3 Shapes Ortho analyzer software version 2019)

Methodology

Two sets of maxillary rubber base impressions were taken from 20 random patients in our department. Impressions were disinfected by immersion in diluted hypochlorite solution followed by rinsing the impression adequately.

Following that, the samples were split into three groups:

  1. Group A: Manual measurement of the stone cast The stone cast poured from the first rubber base impression, was measured manually employing a digital vernier a calliper with a 0.01 mm accurateness (Figure 6).

  2. Group B: Direct scan of the impressionThe second rubber base impression was measured by the lab scanner (Figure 7).

  3. Group C: Scanned stone castThe lab scanner was used to scan and measure the stone casts utilized in group A (Figure 8).

In the present study, the following metrics have been utilized:

Mesio-distal width, Intercanine Distance, Inter first premolar width, Inter second premolar width, Intermolar width, Arch Perimeter, Arch length, Buccolingual width and Clinical crown height.

Statistical Tests

Each parameter was measured in 3 Shapes ortho analyzer software version 2019.

Figure 1

Maxillary perforated impression trays

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image1.png
Figure 2

Condensation C silicone elastomeric impression material

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image2.png
Figure 3

Type III Dental stone (Orthokal)

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image3.png
Figure 4

Digital vernier calliper

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image4.png
Figure 5

3Shape E3 Lab scanner

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image5.png

Figure 6

Manual measurement being made on a stone cast by a digitalvernier calliper.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image6.png
Figure 7

Close up of a maxillary impression being scanned.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image7.png
Figure 8

Scanning of the stone cast by 3shape lab scanner

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image8.png

A power analysis was performed; For an 80% likelihood, 20 models per category were needed, with a standard deviation of 0.2 mm and a variance of 0.18 predicted. The IBM Statistical Package for Social Services (SPSS) version 21 program was used to modify the measurements once they had been gathered, saved, and stored in Excel. Descriptive statistics were generated. The one-way ANOVA technique (Analysis of Variance) was used for the statistical analysis of all measurements. The significance level was 5%.

Results

Descriptive statistics

Descriptive statistics depicts that there was no statistically significant difference between the mean mesiodistal width, mean clinical crown height, mean buccolingual width, the mean of inter canine, inter first premolar, inter second premolar, inter molar distance, arch perimeter & arch length of all the three groups. Graph 1, Graph 2, Graph 3 depict the mean mesiodistal width, mean clinical crown height and mean buccolingual width of group A, Group B and Group C.

Graph 1

Mean mesiodistal width of Group A, Group B and Group C.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image9.png

Figure 9

Mean clinical crown height of Group A, Group B and Group C.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image10.png

Figure 10

Mean buccolingual width of Group A, Group B and Group C.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/aa9eb7ab-e45c-4182-b471-d71fca80f3e6image11.png

Inferential statistics

Inferential statistics show that the One-way ANOVA test for mesio-distal width, clinical crown height, buccolingual width inter canine, first premolar, second premolar, molar distance, arch perimeter & arch length between Group A, Group B and Group C showed no statistically significant difference.

Table 1

One way ANOVA test for inter canine, first premolar, second premolar, molar distance, arch perimeter & arch length between Group A, Group B and Group C.

Between Group A, Group B and Group C

Sum of Squares

Degrees of Freedom

Mean Square

F Value

P Value

ICD

Between Groups

0.129

3

.504

0.996

.40

Within Groups

8.050

57

.141

Total

9.179

59

IFPM

Between Groups

.113

2

.057

1.829

.170

Within Groups

1.768

57

.031

Total

1.881

59

ISPM

Between Groups

.014

2

.007

.014

.986

Within Groups

29.232

57

.513

Total

29.246

59

IMD

Between Groups

.431

2

.215

.062

.940

Within Groups

196.818

57

3.453

Total

197.249

59

AP

Between Groups

.005

2

.003

.000

1.000

Within Groups

2449.115

57

42.967

Total

2449.120

59

AL

Between Groups

.004

2

.002

.000

1.000

Within Groups

445.111

57

7.809

Total

445.114

59

Discussion

Because of the drawbacks of plaster models, which until recently were rated as the gold standard in treatment planning, digital models have been acknowledged as a replacement.3

Studies by Stevans DR et al. (2006)4 and Zilberman O et al. (2003)5 indicated that measurements taken from digital models had a high degree of reproducibility, reliability, and validity. Only a few investigations on the accuracy of linear measurements done on digital models and gold standard plaster models were accessible, including those by Camardella LT et al (2020), 6 Keating AP et al (2008), 7 Kiviahde H et al (2017), 8 Bell A et al (2003),9 Sakar T et al (2017), 10 and Kim J et al (2014).11 Therefore, we did this study to compare the accuracy of measurements made on conventional stone casts by digital vernier calliper to measurements made on digital models created by lab scanning of rubber-based impressions and stone casts.

The study's sample size was established at 20, which seemed sufficient because it was significantly larger than the estimated minimum and was comparable to earlier research by Zilberman O et al (2003)5 and Santoro M et al (2003).12 The study's inclusion criteria were in line with earlier research by El-Zanty HM et al (2010). 13 According to Sousa MVS et al (2012), 14 tooth crowding has been observed to make it difficult to perform linear measurements on dental casts, which has led to its exclusion in certain prior studies as the ones by Wiranto MG et al (2013), 15 Yoon JH et al (2018), 16 and Hassan WNW (2016). 17 We chose to include crowding in our study because it is a type of malocclusion that orthodontists regularly deal with.

Our study's conclusions revealed that there was great agreement in linear dental measurements between stone casts and digital models. No statistically significant changes were discovered when the measurements between the manual and digital models were evaluated using the descriptive statistics. The results of the one-way Anova test likewise demonstrated that there was no statistically significant difference between the three groups. The result of our study was consistent with the studies done by Kim J et al (2016), 11 Kiviahde H et al (2017), 8 Labib MA et al (2020) 3 and Camardella LT et al (2020).6

In the earlier research undertaken by Verma et al (2019), 18 Santoro M et al (2003) 12 and Gayasso SIJ et al (2018) 19 the comparisons between digital and plaster models resulted in significant differences in some parameters. Contrarily, Abizadeh N et al (2012)20 discovered parameters with good repeatability and reproducibility when taking into account both digital and manual procedures, which is consistent with the current investigation. These parameters included inter-canine and inter-molar widths, where it was simpler to locate landmarks.

In the work of Verma et al (2019), 18 the maxillary canines' mesiodistal values on digital models typically revealed highest variance and should be taken into account with caution during measurement. The dimensions may not be accurate because of the canine region's curved arch. Considering the excellent surface detail reproduction on the models created by pouring a more dimensionally stable and accurate rubber base impression material in comparison to the alginate used by Verma et al. (2019), our study did not find any statistically significant differences in the mesiodistal measurement of canines.

Also, measurement errors which could have been there were taken care by clearly stating that landmarks and their extensions.

In a prior study, Santoro M. et al. (2003)12 came to a finding that the estimations of tooth width for each of the measured teeth varied between the plaster and digital model groups. The digital measures were smaller than their counterpart. They suggested that the shrinking of the alginate during shipping and the various pouring times could be responsible for this result. Due to the inclusion of a dimensionally more stable rubber base imprint material, our study could readily avoid these mistakes.

Additionally, in our study, many scans of the same model were taken from various angles in order to achieve more accurate scans. The data from each of these scans was then combined using specialized software (3shape ortho analyser) to a model.

Scanned digital models still have some practical limits when used in orthodontic settings. It can be time-consuming and laborious to scan existing models, which big clinics and institutes might have in plenty. The software's steep learning curve and myriad visualization tools could result in measurement errors. The protection of electronic file data is a different issue. Access to digital study models should be password-protected, as with all other patient records, and for further protection, scanned models should only be transferred with a numbered reference so that the model remains anonymous.20

Insolvency of the maker, failure of the computer or software, or other dangers linked with digitalization could render the models permanently or for an extended period of time inaccessible. The biggest financial drawback of digital models is their expensive price.

Our study does have some limitations. Accurate point placement proved challenging despite the software's rotation and magnification features. Because we restricted our investigation to maxillary models, we were unable to assess interarch metrics like overbite and overjet.

The clinical accuracy and dependability of recently launched scanning hardware and software should be evaluated in the future. Along with this, the factors that haven't been fully taken into account in the literature thus far include related expenditures, the amount of time needed, and the preferences of the patient. We must recognize that human error can undermine the accuracy of many measures. We need multiple innovations across a wide range of sectors to overcome this significant issue.

Conclusion

It is safe to claim that digital models can be extremely accurate and valuable in the clinical setting when utilized in conjunction with clinical data and other diagnostic tools.

Source of Funding

None.

Conflict of Interest

None.

References

1 

DD Moreira BF Gribel GDR Torres KDF Vasconcelos DQD Freitas GMB Ambrosano Reliability of measurements on virtual models obtained from scanning of impressions and conventional plaster modelsBraz J Oral Sci2014134297302

2 

N Brusco M Andreetto L Lucchese S Carmignato GM Cortelazzo Metrological validation for 3D modeling of dental plaster castsMed Eng Phys200729995466

3 

MA Labib AR El-Beialy KH Attia Evaluation of the accuracy of digital models obtained using intraoral and extraoral scanners versus gold standard plaster model (diagnostic accuracy study)Open Med Imaging J202010315163

4 

DR Stevens C Flores-Mir B Nebbe DW Raboud G Heo PW Major Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurementsAm J Orthod Dentofac Orthop20061296794803

5 

O Zilberman J Huggare KA Parikakis Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic modelsAngle Orthod20037333016

6 

LT Camardella EM Ongkosuwito EW Penning AM Kuijpers-Jagtman OV Vilella KH Breuning Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scannersKorean J Orthod20205011325

7 

AP Keating J Knox R Bibb AI Zhurov A comparison of plaster, digital and reconstructed study model accuracyJ Orthod2008353191201

8 

H Kiviahde Inter-arch digital model vs. manual cast measurements: Accuracy and reliabilityCranio20173642227

9 

A Bell AF Ayoub P Siebert Assessment of the accuracy of a three-dimensional imaging system for archiving dental study modelsJ Orthod200330321923

10 

T Sakar K Orhan A Sinanoglu O Tosun U Oz Assessment of the Accuracy of Orthodontic Digital Models in Dental EducationEurasia J Math Sci Technol Educ2017138546573

11 

J Kim MO Lagravere Accuracy of Bolton analysis measured in laser scanned digital models compared with plaster models (gold standard) and cone-beam computer tomography imagesKorean J Orthod2016461139

12 

M Santoro S Galkin M Teredesai OF Nicolay TJ Cangialosi Comparison of measurements made on digital and plaster modelsAm J Orthod Dentofac Orthop200312411015

13 

HM El-Zanaty AR El-Beialy A El-Ezz AM Attia KH El-Bialy AR Mostafa Assessment of the accuracy of a three-dimensional imaging system for archiving dental study modelsJ Orthod200330321923

14 

MV Sousa EC Vasconcelos G Janson D Garib A Pinzan Accuracy and reproducibility of 3-dimensional digital model measurementsAm J Orthod Dentofac Orthop2012142226973

15 

MG Wiranto WP Engelbrecht HE Nolthenius WJ Van Der Meer Y Ren Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressionsAm J Orthod Dentofac Orthop201314311407

16 

JH Yoon HS Yu Y Choi TH Choi SH Choi JY Cha Model analysis of digital models in moderate to severe crowding: in vivo validation and clinical applicationBio Med Res Int2018841460510.1155/2018/8414605

17 

W Hassan SA Othman CS Chan R Ahmad SN Ali Abd Rohim A. Assessing agreement in measurements of orthodontic study models: Digital caliper on plaster models vs 3-dimensional software on models scanned by structured-light scannerAm J Orthod Dentofac Orthop2016150588695

18 

RK Verma SP Singh S Verma V Kumar NR Bhupali S Arora Comparison of reliability, validity, and accuracy of linear measurements made on pre- and posttreatment digital study models with conventional plaster study modelsJ Orthod Sci20198116

19 

S Gayosso Difference between manual and digital measurements of dental arches of orthodontic patientsMedicine2018972215

20 

N Abizadeh DR Moles O Neill J Noar Digital versus plaster study models: how accurate and reproducible are they?J Orthod20123931519



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International, which allows others to remix, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

  • Article highlights
  • Article tables
  • Article images