Introduction
Class II malocclusion being a common maxillο-mandibular skeletal discrepancy, has been reported in 23% children, 15% youths and 13% adults. 1, 2 It manifests as maxillary prognathism, mandibular retrognathism, or a combination of both. 3 Removable functional appliances like the Activator, Bionator and Twin Block, though effective are dependent upon patient compliance for clinical success. However, Fixed functional appliances (FFAs) being non-compliant Class II correctors, do not depend upon patient compliance for a favourable treatment outcome. AdvanSyncTM FFA was introduced in 2008 and later upgraded to the AdvanSync 2TM FFA (Ormco Corporation) in 2012 which is reported to produce greater skeletal changes than its contemporaries.4, 5, 6
AdvanSyncTM 2, developed by Terry and Bill Dischinger, is a rigid fixed tooth-borne functional appliance. The appliance consists of crowns cemented on the maxillary and mandibular first permanent molars with interconnecting telescopic rods that posture the mandible forward to promote mandibular growth at the condylar region. 6 In addition to enhancing mandibular growth, AdvanSyncTM 2 is also reported to restrain further maxillary growth, hence producing a ‘headgear effect’.7
Though literature is replete with evidences in favour of FFAs,8, 9, 10 this study was conducted to provide comprehensive data on the skeletal, dental, soft-tissue and airway changes produced by AdvanSync TM 2 appliance in correction of skeletal Class II malocclusion.
The null hypothesis for the study was ‘There are no changes in skeletal, dental, soft-tissue and airway parameters following treatment of skeletal Class II malocclusion with AdvanSync TM 2 fixed functional appliance.
Sample size calculation
The sample size for the study was calculated based on the formula described by Pandis with a 95% level of significance and 80% power. 11 The sample size obtained to test the null hypothesis was 12. The sample characteristics are depicted in Table 1.
Materials and Methods
This retrospective study was conducted in the department of Orthodontics and Dentofacial Orthopedics of a tertiary care government dental establishment following ethical clearance obtained by the institutional ethical committee. The inclusion criteria comprised of patients diagnosed with skeletal Class II malocclusion due to mandibular retrognathism. Cases with complete pre-functional and post-functional records, permanent dentition with symmetric Class II molar relation bilaterally, an overjet >5mm, a positive Visual Treatment Objective (VTO) indicating functional appliance therapy and treated with AdvanSync TM 2 fixed functional appliance were chosen to be included in the study sample. Exclusion criteria comprised of patients with history of previous orthodontic treatment/ trauma/ systemic disorders affecting the bone metabolism. Patients with neuromuscular disorders/ TMJ pathology, syndromes including cleft lip and palate and skeletal asymmetry were excluded.
Based on the set inclusion and exclusion criteria, pre-treatment records (T0) of 12 patients were taken from the departmental archives. A representative case is shown in Figure 1. This study aimed to analyse the effects of the AdvanSync TM 2 (Ormco AdvanSync TM II) independent of a fixed preadjusted edgewise appliance. This method of application was derived from Ghaffar et al who similarly compared the dentoskeletal efficacy of the AdvanSync TM 2 to another functional appliance. 12 The functional phase lasted for 6-8 months until unrestrained Class I molar and canine relation was observed along with optimum facial esthetics. At this stage, post-functional records (T1) were taken and the AdvanSync TM 2 appliance was removed. Following functional phase, the patients underwent fixed orthodontic treatment using a 0.022” MBT pre-adjusted edgewise appliance. The dentition was leveled and aligned using standard archwire sequence followed by settling of the occlusion.
The pre-functional and immediate post-functional lateral cephalograms were hand-traced and the selected parameters shown in Figure 2 were measured by single operator. To check for intra-operator reliability, records of 10 cases were selected randomly after one week and landmark identification, tracing and measurements were repeated by the same operator. Intra-operator reliability coefficient was calculated and was found to be high (0.98-1).
Statistical analysis
The data was statistically analysed using Statistical Package for Social Sciences (SPSS ver 23, IBM Corporation, USA) for Microsoft Windows. Paired parametric data (pre-functional v/s post-functional) was tested using paired t-test.
Table 1
Parameters |
(n = 12) |
Age (Years) |
14.25 ± 0.75 |
Gender |
|
Male |
6 (50.0%) |
Female |
6 (50.0%) |
CVMI Stage |
4.50 ± 0.52 |
Table 2
Results
Changes achieved in skeletal parameters are depicted in Figure 3 and Table 2. Skeletal parameters such as SNB, Wits, maxillo-mandibular differential, estimated length of mandible (EL-mand), Articulare angle, Gonial angle, Björk’s sum, basal plane angle, Sn-GoGn, lower anterior facial height (LAFH), Na-perp-Pog differed significantly at T1 (p value<0.05). Skeletal parameters SNA, Na-perp-PtA, UAFH-LAFH ratio, Y-axis, Saddle angle, Jaraback’s ratio, estimated length of maxilla (EL-max) did not differ significantly at T1 (p value>0.05).
Statistically significant changes at T1 were observed for dental parameters U1-NA (angular and linear), L1 to NB (angular and linear), U1-SN angle, IMPA, Inter-incisal angle, L1 to A-Pog, U1 to A-Pog (p value <0.05). U1 to A-vert did not show a statistically significant change at T1. Dentoalveolar changes are shown in Figure 4 and Table 2.
Soft tissue parameters, facial convexity and nasolabial angle revealed statistically significant results at T1 (p value<0.05), while UL to E-line and LL to E-line changes were not found to be significant (p value>0.05) as shown in Figure 5 and Table 2. For airway parameters statistical significance was obtained in the changes obtained in posterior pharyngeal airway space (p value <0.05), while superior airway space, hyoid distance and hyoid angle changes were not statistically significant (p value >0.05). Airway changes are shown in Figure 6 and in Table 2.
Discussion
The corrective effect of fixed functional appliances is cumulative of dental and skeletal changes which result in an improvement in the overall esthetics and function. 13 Cacciatore et al in a systematic review reported a 1-degree decrease in ANB, and -3.5mm to 2mm improvement in the Wits and maxillomandibular differentials with the use of functional appliances. 14
Skeletal changes
In the present study, AdvanSync TM 2 produced a statistically significant decrease in the ANB (mean change of 2.04 degrees) by producing a significant increase in the SNB (2.62 degrees). The sagittal correction of the mandible was observed as an improvement in the Wits appraisal (-2.25) and maxillomandibular differential (3.50mm mean increase). Similar results have been reported by Ghaffar et al. Bhonsale et al and Kaushik et al. 11, 15, 16
The results of the current study differed from those reported by Mofty et al and Al-Jewair et al who reported on the ‘headgear effect’ of the appliance. 17, 18 In the present study, the sagittal correction in ANB had been significantly contributed to by an increase in the SNB (mean 2.62-degree increase). Mandibular growth was evident by the significant changes in the maxilla-mandibular differentials in the current study. The increase in length of the mandible (Co-Gn) (mean 3.50mm) was found to be statistically significant. Jayachandran et al also reported a mean increase of 7.53 mm of Co-Gn and 5.58mm in Mx-Md differential. 6
Statistically significant improvement in the facial height with a mean increase of 2.62 mm in the lower anterior facial height (ANS-Me) were also found in the present study being supported by similar reports by Jayachandran et al, Pyarilal et al and Kaushik et al. 6, 16, 19 Improvement in the lower anterior facial height was supported by an equivalent increase in the gonial angle, basal plane angle, SN-GoGn angle and Y-axis, all denoting the downward rotation of the mandible in addition to its sagittal advancement by the functional appliance.
No statistically significant change in the maxillary growth (EL-max -0.88mm) was observed in the present study. Literature on the maxillary restrictive effect of the appliance is varied with some studies reporting significant skeletal growth restriction while others support no restrictive effect of functional appliances. 13 The dichotomy in maxillary skeletal growth restriction by the appliance can be explained by the method of usage of the appliance between the current study and previous reports. The current methodology is similar to a study by Ghaffar et al, which cites similar non-significant effects on maxillary skeletal. 11
Dental changes
In the present study, angular and linear measurements of U1 to NA (Steiner Analysis) were observed to decrease by 4.25 degree and 1.63 mm respectively, while U1 to SN decreased by 3.58 degrees. Though the upper incisors showed statistically significant correction in inclination, the lower incisors proclined significantly with AdvanSync TM 2. IMPA increased by a mean of 3.08 degrees, L1 to NA (angular) increased by 3.25 degrees, L1 to NA (linear) increased by 1.16mm, and L1 to Pt A-Pog by 1.62mm. Al-Jewair et al reported similar changes in L1 to Pt A-Pog of 0.9mm and IMPA increase of 3.8 degree in the AdvanSync TM group. 5 Ghaffar et al reported similar results of a 2.13-degree increase in IMPA. 11 These results suggest AdvanSync TM 2 to produce limited flaring of incisors when used independent of a fixed orthodontic edgewise appliance therapy.
Soft tissues
AdvanSync TM 2 produced a retraction of the upper lip relative to Rickett’s E-line by 0.50mm. This could be explained by the maxillary restraining effect of the appliance. The lower lip to E-line increased by 0.17mm in Group 2 and can be due to the increase in the mandibular projection due to sagittal advancement and the dentoalveolar effects of the appliance on the lower incisors. Nasolabial angle showed a significant increase of 6.79 degrees, similar to the report by Bhonsale et al.15 Contrary to the current study, Jayachandran et al reported larger changes in upper lip retraction of 2.54mm while lower lip projection increased by 1mm. 6 Their findings can be attributed to the higher dentoalveolar effects in both maxillary and mandibular parameters, as seen in the AdvanSync TM sample.
Airway changes
Treatment with AdvanSync TM 2 produced statistically significant improvement in upper airway dimensions by 0.75mm and lower airway dimensional changes of 1.42mm, secondary to its effect on mandibular growth and rotation.
Airway changes secondary to functional appliances therapy are attributable to both sagittal advancement of the mandible and its rotation. These therapeutic skeletal effects of functional jaw orthopaedics could aid in increasing the linear dimension of the airway, especially in cases of severe mandibular retrusion. Notwithstanding this, functional appliances are not the primary therapeutic approach in patients of airway and breathing disorders.
Limitations of the study
Statistically significant results were obtained for the objectives in the study, though, the following limitations were noted:
Study sample size was small and limited to a single centre for the present study. Future prospective and randomized controlled trials in a multi-centric study design are recommended.
The timeframe of the present study was short, and the long-term stability of the changes could not be ascertained. Studies with long-term follow-up of changes after fixed functional appliance therapy are indicated.
Conclusion
Based on the results of the present study, it can be concluded that:
The null hypothesis was rejected due to changes observed in skeletal, dental, soft tissue and airway parameters following treatment with AdvanSync TM 2 FFA.
AdvanSync TM 2 proved to be effective in the correction of Skeletal Class II malocclusion in growing patients.
Skeletal Class II correction with AdvanSync TM 2 was primarily by dentoalveolar changes and limited skeletal changes.
AdvanSync TM 2 produced improvement in facial esthetics as examined by the soft-tissue changes.
Improvements in linear airway cephalometric parameters were noted post-AdvanSync TM 2 therapy.